# TA -- Thermal Analysis Simulator Simulate simultaneous TGA / DTA / DTG / MS experiments using [Cantera](https://cantera.org). TA models a sample crucible inside a furnace connected by a heat-transfer wall. The furnace follows a user-defined temperature program (ramps, isothermal holds, cooling segments) while the sample heats through the wall, producing realistic thermal lag. Chemical reactions in the sample generate the DTA and MS signals; phase filtering separates condensed-species mass loss (TGA) from volatile products (MS). ## How it works ```text Temperature Program --> TASimulator --> SimulationResult | +---------------------+-------------------+ | | | compute_tga() compute_dta() compute_ms() | | | compute_dtg() | | | | | +---------------------+-------------------+ | plot_ta_figure() ``` ```{toctree} :maxdepth: 2 :caption: Contents installation quickstart temperature_programs api ```